New 6850 double beam spectrophotometer with variable bandwidth

    كود المنتج
    1504055
    بلد الصنع
    المملكة المتحدة
    متوفر في المخزن
    0 جم
    الوصف
    • Double beam spectrophotometer with highly stable optics • Variable spectral bandwidth 0.5, 1, 2, 4, 5nm • Integrated user interface • USB port for data storage • Conforms to European Pharmacopeia requirements • Jenway Prism PC software included as standard • Extensive range of accessories available • 1 year warranty

    The new 6850 introduces the first double beam spectrophotometer with a variable spectral bandwidth into the Jenway range. The highly stable optics and two detectors measure the sample and reference simultaneously optimising measurement accuracy. The 6850 has measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA/RNA and protein analysis.

    Jenway Prism PC software is supplied as standard and offers additional functionality with preloaded methods for DNA/RNA and protein analysis, as well as extensive post-measurement tools, unlimited results saving and easy export of data.

    The 6850 double beam spectrophotometer is ideal for quality control, general research, pharmaceutical, biochemical and clinical laboratory applications.

    Installation Qualification and Operation Qualification (IQ/OQ) is available for the 6850. Jenway do not supply the filters which are required to complete the IQ/OQ but we can recommend a supplier. For more information on IQ/OQ please contact Jenway Help.

    Technical Specification

     

    Parameter 6850
    Wavelength range 190 to 1100nm
    Wavelength resolution 0.1nm
    Wavelength accuracy ± 0.3nm (at 0.5 and 1nm bandwidth) ± 0.5nm (at 2, 4 and 5nm bandwidth)
    Wavelength reproducibility ± 0.2nm
    Spectral bandwidth Variable 0.5, 1, 2, 4, 5nm
    Photometric range - 0.3 to 3.0A 0 to 200%T
    Photometric accuracy ± 0.002A (0- 0.5A) ± 0.3% T (0- 100%T)
    Photometric reproducibility ± 0.001 Abs (0 to 0.5 Abs) ± 0.002 Abs (0.5 to 1.0 Abs) 0.15%T (0- 100%T)
    Resolution 0.1%T, 0.001A
    Stray light < 0.05%T at 220 and 360nm
    Noise 0.0005A
    Stability ± 0.001A/h at 500nm after 15 min warm up
    Multi-wavelength Up to 10 wavelengths, up to 20 wavelengths with PC software
    Calculations Ratio, difference, formulae with factors
    Spectrum range Any range between 190 and 1100nm
    Scan speed 100 to 2000nm/min
    Scan interval 0.1, 0.2, 0.5, 1, 2 or 5nm
    Analysis Auto peaks and valleys, zoom . Addition, subtraction, peak ratios, smoothing, area under curve, wavelength table, derivatives, overlay with PC software
    Kinetics Up to 12 hours with time intervals of 0.1, 0.2, 0.5, 1, 2, 5, 10 or 30 seconds
    Analysis Slope and formula of line of best fit between any two points
    Quantitation points Up to 3 wavelengths
    Quantitation Calibration Blank with up to 10 standards or factor
    Concentration range 0- 99999
    Calibration Blank with standards or factor
    DNA/ RNA and Protein DNA/RNA Ratio, concentration, A320 correction
    Light source Tungsten halogen and Deuterium lamps
    Lamp changeover 325 to 370nm selec table
    Outputs USB and parallel
    Operating system: Windows 2000, XP, Vista, Windows 7
    Electrical supply 120VA, 220/ 110V, 50/ 60Hz
    Size (w x d x h) 600 x 450 x 200mm
    Weight 22kg
     

     

    Ordering Information

     

    Part Code Description
    6850/ 230V 6850 double beam spectrophotometer, supplied fitted with single 10x10mm cuvette holder in sample and reference position, instruction manual, power cables, PC software on CD ROM with USB connection cable and dongle, 4GB USB memory stick, 2 x quartz cuvettes, 4 x glass cuvettes and FREE dust cover and 230V power supply
    6850/ 115V 6850 double beam spectrophotometer, supplied fitted with single 10x10mm cuvette holder in sample and reference position, instruction manual, power cables, PC software on CD ROM with USB connection cable and dongle, 4GB USB memory stick, 2 x quartz cuvettes, 4 x glass cuvettes and FREE dust cover and 115V power supply
     

     

    The 6850 is now available with IQ/OQ documentation

     

    Part Code Description
    6850/ 230V/ IQOQ 6850 Double Beam Spectrophotometer as 6850/ 230V with IQ/OQ documentation
    6850/ 115V/ IQOQ 6850 Double Beam Spectrophotometer as 6850/ 115V with IQ/OQ documentation
    مواصفات المنتج
    بلد الصنعالمملكة المتحدة
    Description

    The new 6850 introduces the first double beam spectrophotometer with a variable spectral bandwidth into the Jenway range. The highly stable optics and two detectors measure the sample and reference simultaneously optimising measurement accuracy. The 6850 has measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA/RNA and protein analysis.

    Jenway Prism PC software is supplied as standard and offers additional functionality with preloaded methods for DNA/RNA and protein analysis, as well as extensive post-measurement tools, unlimited results saving and easy export of data.

    The 6850 double beam spectrophotometer is ideal for quality control, general research, pharmaceutical, biochemical and clinical laboratory applications.

    Installation Qualification and Operation Qualification (IQ/OQ) is available for the 6850. Jenway do not supply the filters which are required to complete the IQ/OQ but we can recommend a supplier. For more information on IQ/OQ please contact Jenway Help.

    Technical Specification

     

    Parameter 6850
    Wavelength range 190 to 1100nm
    Wavelength resolution 0.1nm
    Wavelength accuracy ± 0.3nm (at 0.5 and 1nm bandwidth) ± 0.5nm (at 2, 4 and 5nm bandwidth)
    Wavelength reproducibility ± 0.2nm
    Spectral bandwidth Variable 0.5, 1, 2, 4, 5nm
    Photometric range - 0.3 to 3.0A 0 to 200%T
    Photometric accuracy ± 0.002A (0- 0.5A) ± 0.3% T (0- 100%T)
    Photometric reproducibility ± 0.001 Abs (0 to 0.5 Abs) ± 0.002 Abs (0.5 to 1.0 Abs) 0.15%T (0- 100%T)
    Resolution 0.1%T, 0.001A
    Stray light < 0.05%T at 220 and 360nm
    Noise 0.0005A
    Stability ± 0.001A/h at 500nm after 15 min warm up
    Multi-wavelength Up to 10 wavelengths, up to 20 wavelengths with PC software
    Calculations Ratio, difference, formulae with factors
    Spectrum range Any range between 190 and 1100nm
    Scan speed 100 to 2000nm/min
    Scan interval 0.1, 0.2, 0.5, 1, 2 or 5nm
    Analysis Auto peaks and valleys, zoom . Addition, subtraction, peak ratios, smoothing, area under curve, wavelength table, derivatives, overlay with PC software
    Kinetics Up to 12 hours with time intervals of 0.1, 0.2, 0.5, 1, 2, 5, 10 or 30 seconds
    Analysis Slope and formula of line of best fit between any two points
    Quantitation points Up to 3 wavelengths
    Quantitation Calibration Blank with up to 10 standards or factor
    Concentration range 0- 99999
    Calibration Blank with standards or factor
    DNA/ RNA and Protein DNA/RNA Ratio, concentration, A320 correction
    Light source Tungsten halogen and Deuterium lamps
    Lamp changeover 325 to 370nm selec table
    Outputs USB and parallel
    Operating system: Windows 2000, XP, Vista, Windows 7
    Electrical supply 120VA, 220/ 110V, 50/ 60Hz
    Size (w x d x h) 600 x 450 x 200mm
    Weight 22kg
     

     

    Ordering Information

     

    Part Code Description
    6850/ 230V 6850 double beam spectrophotometer, supplied fitted with single 10x10mm cuvette holder in sample and reference position, instruction manual, power cables, PC software on CD ROM with USB connection cable and dongle, 4GB USB memory stick, 2 x quartz cuvettes, 4 x glass cuvettes and FREE dust cover and 230V power supply
    6850/ 115V 6850 double beam spectrophotometer, supplied fitted with single 10x10mm cuvette holder in sample and reference position, instruction manual, power cables, PC software on CD ROM with USB connection cable and dongle, 4GB USB memory stick, 2 x quartz cuvettes, 4 x glass cuvettes and FREE dust cover and 115V power supply
     

     

    The 6850 is now available with IQ/OQ documentation

     

    Part Code Description
    6850/ 230V/ IQOQ 6850 Double Beam Spectrophotometer as 6850/ 230V with IQ/OQ documentation
    6850/ 115V/ IQOQ 6850 Double Beam Spectrophotometer as 6850/ 115V with IQ/OQ documentation
    Short Description• Double beam spectrophotometer with highly stable optics • Variable spectral bandwidth 0.5, 1, 2, 4, 5nm • Integrated user interface • USB port for data storage • Conforms to European Pharmacopeia requirements • Jenway Prism PC software included as standard • Extensive range of accessories available • 1 year warranty
    Write Your Own Review
    أرسل لنا تقييمك: New 6850 double beam spectrophotometer with variable bandwidth
    رأيك يهمنا