Combined pH and Conductivity Meter

    كود المنتج
    1504039
    بلد الصنع
    المملكة المتحدة
    متوفر في المخزن
    0 جم
    الوصف
    3540 Bench Combined Conductivity/pH Meter

    • Simultaneous display of pH and conductivity
    • 2 independent channels to prevent interference between probes
    • Additional modes for resistivity, salinity, TDS and mV
    • Data logger with auto save/print options
    • Storage of up to 500 readings (250 for each mode)

    The 3540 is ideal for use in all laboratories where pH and conductivity analyses are required. The setup menu gives quick and easy access to the whole range of instrument, pH and conductivity measurement options. Calibration of both channels is automatic, with the option to select 1, 2 or 3 calibration points. The pH channel can also display mV values if required.

    Technical Specification

     

    Parameter 3540
    pH range - 2.000 to 20.000
    pH resolution 0.001/ 0.01/ 0.1
    pH accuracy ± 0.003
    mV range ± 1999.9mV
    mV resolution 0.1mV
    mV accuracy ± 0.2mV
    Conductivity range Auto-selec ted from 0.01µS to 1.999S
    Conductivity resolution 0.01µS to 1mS
    Conductivity accuracy ± 0.5 ± 2 digits
    Temperature range - 10 to 105°C
    Temperature resolution 0.1°C
    Temperature accuracy ± 0.5°C
    ATC and manual 0 to 100°C
    Temperature coefficient 0.00 to 4.00% / °C
    Reference temperature 18, 20, 25°C
    GLP Calibration reminder interval, operator and sample ID and security coded setup
    Outputs Analogue, RS232 and IrDA interface
    Connectors BNC (pH) and 7-pin DIN (conductivity)
    Power 9V AC ± 10% @ 50/ 60Hz
    Size (l x w x d) 210 x 250 x 55mm
    Weight 850g
     

     


    Ordering Information
    Please take note of the power supply required

     

    Part Code Description
    354 001 3540 conductivity/ pH meter supplied with glass combination pH electrode (924 005), glass conductivity probe (K= 1 027 013), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH buffers and UK power supply
    354 101 3540 conductivity/ pH meter supplied with glass combination pH electrode (924 005), glass conductivity probe (K= 1 027 013), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH buffers and US power supply
    354 201 3540 conductivity/ pH meter supplied with glass combination pH electrode (924 005), glass conductivity probe (K= 1 027 013), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH buffers and EU power supply
    مواصفات المنتج
    بلد الصنعالمملكة المتحدة
    Description

    • Simultaneous display of pH and conductivity
    • 2 independent channels to prevent interference between probes
    • Additional modes for resistivity, salinity, TDS and mV
    • Data logger with auto save/print options
    • Storage of up to 500 readings (250 for each mode)

    The 3540 is ideal for use in all laboratories where pH and conductivity analyses are required. The setup menu gives quick and easy access to the whole range of instrument, pH and conductivity measurement options. Calibration of both channels is automatic, with the option to select 1, 2 or 3 calibration points. The pH channel can also display mV values if required.

    Technical Specification

     

    Parameter 3540
    pH range - 2.000 to 20.000
    pH resolution 0.001/ 0.01/ 0.1
    pH accuracy ± 0.003
    mV range ± 1999.9mV
    mV resolution 0.1mV
    mV accuracy ± 0.2mV
    Conductivity range Auto-selec ted from 0.01µS to 1.999S
    Conductivity resolution 0.01µS to 1mS
    Conductivity accuracy ± 0.5 ± 2 digits
    Temperature range - 10 to 105°C
    Temperature resolution 0.1°C
    Temperature accuracy ± 0.5°C
    ATC and manual 0 to 100°C
    Temperature coefficient 0.00 to 4.00% / °C
    Reference temperature 18, 20, 25°C
    GLP Calibration reminder interval, operator and sample ID and security coded setup
    Outputs Analogue, RS232 and IrDA interface
    Connectors BNC (pH) and 7-pin DIN (conductivity)
    Power 9V AC ± 10% @ 50/ 60Hz
    Size (l x w x d) 210 x 250 x 55mm
    Weight 850g
     

     


    Ordering Information
    Please take note of the power supply required

     

    Part Code Description
    354 001 3540 conductivity/ pH meter supplied with glass combination pH electrode (924 005), glass conductivity probe (K= 1 027 013), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH buffers and UK power supply
    354 101 3540 conductivity/ pH meter supplied with glass combination pH electrode (924 005), glass conductivity probe (K= 1 027 013), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH buffers and US power supply
    354 201 3540 conductivity/ pH meter supplied with glass combination pH electrode (924 005), glass conductivity probe (K= 1 027 013), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH buffers and EU power supply
    Short Description3540 Bench Combined Conductivity/pH Meter
    Write Your Own Review
    أرسل لنا تقييمك: Combined pH and Conductivity Meter
    رأيك يهمنا